Changes since UPDATEman version 2.0.

  - Correction of an in version 1.5r03 introduced failure: If the board
    contained elements without belonging symbols in the schematic,
    then an error message was distributed according to which entries should
    be missing in the library index although the entries were available.
  - Now the layers are always shown on a numeric order in the display window.
  - Now the names of project files also may contain blanks.
  - At the check on more as 2 names or 2 values per package other texts
    are remaining unconsidered in the packages now.
  - If a project isn't consistent, the help is called upon for UPDATEman.
  - If the belonging counterpart isn't loaded to a board or schematic,
    then this is loaded by UPDATEman now automatically.
  - If a package is missing in the board, then the warning seems no longer
    wrongly " ... has more names or values than in the ... " now.
  - If a case is missing in the board, then this is documented in the update
    report at the element in question now by the entry of "no-one" 
    under "old case".
  - The one of UPDATEman produced DRC file (...) _temp.dru is deleted by
    Eagle automatically after closing.
  - Libraries are accepted into the index file with blanks in their name now.
  - Now libraries are accepted into the index file which no cases contain.
  - By means of "Index B" no more separate entries for cases are carried out
    now. Only still normal entries are appended to an existing index by
    single libraries.
  - If feeding the "Index A" is broken off by clicking the stop symbol,
    then - when starting the ULPs once more - the complete list of the
    libraries is taken advantage of fed now instead of continuing like till
    only from the place of the termination.
  - Now in the "Part List" for the schematic the sheets are listed.
  - Now in the "Part List" for the schematic components are listed which
    although have a package, however no symbol. 
  - Elements without pads are indicated now in the "Part List" for the board.
  - Elements with pads are marked now in the "Part List" for the board if
    there isn't any package to this in the schematic.
  - In the dialog "Conversion of the Packages of the Board" at missing
    package entries in the catalog the respective package entry is taken now
    in the editing line at the double click on a line of the index list.
  - Now UPDATEman is able to use elements in the board with pads which are
    not part of any device in the schematic.
  - With 3 new options the Eagle options 'Optimizing', "Ckeck Connects" as
    well as 'Auto set junction' can swiched on or off after closing UPDATEman.
  - If at the generating of "Index A" the overwriting of an available library
    index is denied, then the dialog "Library Index new or overwrite" seems
    renewed.
  - Now the connections are compared with each other in the old and new board.
  - Now the pins of the symbols in the new schematic may have another length
    or postition or the symbols themselves may have another origing than in
    the old schematic.
  - If UPDATEman is started with the same project repeated, then the files
    "..._new.brd" and respectively "..._new.sch" stored before can be deleted
    from UPDATEman.
  - The values are only overwritten at devices with the attribute "Value
    On". If the values of those devices with the attribute "Value Off",
    at with the values in the library of the new schematic differing of the
    values of the devices in the old schematic, shall be overwritten,
    then this can be archieved by the new option "Values of the components
    with attribute 'Value Off' overwrite".
  - Net lines and symbols whitch does not lie exactly on the 50/100-mil grid
    are moved after converting on grid.
  - Changes in the dialogs "Editing the Device Names" und "Editing the
    Package Names":
    - If in the dialog "Conversion of the Devices of the Schematic" or
      "Conversion of the Packages of the Board" a device or package is
      selected witch is contained repeatedly in the library index, then a
      selection window appears now.
    - After selection of the device/package to be converted the focus is
      lying now on the possible new device/package - provided that the old
      device/package name is contained in the library index.
    - If the libraries listed in the index are in use, then the lines
      in question are labeled.
    - It is shown now whether the device or package to be converted is
      available in the library index or not.
    - It is no longer possible to carry out an entry into the catalog if
      the selected name isn't contained in the index.
    - It is no longer possible to carry out an entry into the catalog,
      if a device or a package is selected whose library isn't in use.
  - Various changes for the improvement in the handling.
  - Text of the help extended.
  - Release as version 2.1

2.1r02
  - Changes in the dialogs "Editing the Device Names" und "Editing the
    Package Names":
    - After choice of the device/package to be converted the focus then
      lies on the possible new device/package, too, if the old names have
      an expansion with "@n".
    - Bugs in the status advertisement and missing focus on a device/package
      were eliminated.
    - A search for a device/package is possible by means of the wildcard "*"
      now.
  - A faulty text rotation in the schematic at smashed symbols corrected.
2.1r03
  - There is the new option 'Replace single devices' now. The REPLACE command
    being missing in Eagle for the schematic is made possible with that.
  - Release as version 2.2

2.2r01
  - Version requirement for Eagle changed to 4.14.
  - If UPDATEman is called with an older Eagle version than 4.14, a reference
    to this required version is then carried out.
  - Release as version 2.21

2.21r01
  - Bug eleminated in case a device with a single gate has a name allocated by
    the user. (Device couldn't be ADD because of missing coordinates.)
  - Program flow accelerated.
  - Bug eleminated in case there are drawing frames from more than one "gate"
    (no pads).
  - New button 'Net Comparison'. A renewed comparison can be carried out after
    a conversion also after change at the converted schematic.
  - Release as version 2.22

2.22r01
  - Texts smashed from the packages are moved again to the coordinates like
    in the origin file. Bug was introduced in version 2.2.
  - Fixed: If only 1 gate of a component was placed and the symbols for the
    power supply were put on another sheet, the component couldn't be placed.
  - If components are converted which more layer are used in the board than
    in the old project, then the new layer appear in the display window now,
    put in order in a numeric sequence.
2.22r02
  - If a new component includes 2 names or value entries each, then these may
    be located on the two board sides now.
  - In the report file " ... _too_much_names.txt" is shown at the components
    now , whether they have names or values more or less than in the old
    board.
  - Index files can be produced now also under a new name at the "Index B".
  - If new nets are produced and the names put in at the end of the net
    script list when converting, these appear in the fault report now.
  - Release as version 2.23